Initial version of freemodbus master port files have been added to ESP-IDF based on https://github.com/armink/FreeModbus_Slave-Master-RTT-STM32.
The overall repository license, at the time of adding these files, has been BSD 3-clause. However at that time, several port files carried LGPL license headers. As the author of these files confirmed in https://github.com/armink/FreeModbus_Slave-Master-RTT-STM32/issues/61#issuecomment-977828450, this wasn't intentional. ESP-IDF version of modbus master port has been rewritten to target FreeRTOS instead of RT-Thread, but the license headers remained from the original version. This commit corrects this, replacing the license of these files with BSD 3-clause.
Add TCP port files to provide Modbus TCP interface for communication
Add freemodbus add tcp support for common master/slave iface and tcp example based on socket API
The communication between master and slave checked for each example serial_master, serial_slave (use ModbusPoll TCP)
update tcp example according netif changes, fix ci issues
update TCP slave implementation
update example_test.py to to set IP through stdin
update API documentation
event bit instead of semahore to lock communication resource
update default options and master/slave port files
Closes https://github.com/espressif/esp-idf/issues/858
Closes IDF-452
check master read write functions with array of registers)
fix master serial processing code and modbus controller to work with register array
modbus_master: add reading and writing of test value array (58 registers) to check failure is gone
remove parameter temporary buffer from modbus controller to allow more than 24 byte writes
driver: fix issue with TOUT feature
driver: fix uart_rx_timeout issue
driver: fix issue with rxfifo_tout_int_raw not triggered when received fifo_len = 120 byte and all bytes read out of fifo as result of rxfifo_full_int_raw
driver: add function uart_internal_set_always_rx_timeout() to always handle tout interrupt
examples: call uart_internal_set_always_rx_timeout() to handle tout interrupt correctly
examples: update examples to use tout feature
driver: reflect changes of uart_set_always_rx_timeout() function, change uart.c
driver: change conditions to trigger workaround for tout feature in uart.c
driver: change uart_set_always_rx_timeout()
freemodbus: fix tabs, remove commented code
driver: remove uart_ll_is_rx_idle()
add support of modbus master ascii
rename base dir name of master and slave example to be mb_slave, mb_master to avoid conflict with sdio/slave example test
add Kconfig option to enable ASCII and RTU mode separately
update ASCII options + remove cast for errors
added baudrate for examples into Kconfig
updated magic numbers for timer timeout
put ascii private definitions into one file
1. add hal and low-level layer for timer group
2. add callback functions to handle interrupt
3. add timer deinit function
4. add timer spinlock take function
place timer handler functions into IRAM
update timer port handlers
fix communication issues
fix offset issue in example
add kconfig option to place handlers into IRAM
adds timer interrupt handle and free it in vMBXXXPortTimerClose() in master and slave timer port
assign modbus controller interface pointer to NULL in destroy function after free
Using xxx_periph.h in whole IDF instead of xxx_reg.h, xxx_struct.h, xxx_channel.h ... .
Cleaned up header files from unnecessary headers (releated to soc/... headers).
Contains two different component folders per each implementation (serial_master and serial_slave) with concrete ports.
Added common public api for master and slave and common interface for master and slave implementation.
Add support of cmake system (added cmake files).
Added sdkconfig.defaults files for slave and master modbus examples.
Updated make file and KConfig for freemodbus component
Update according to review and fix doxygen warnings
Fix Doxyfile to pass documentation build
Update headers and change interface file names as per review comments
Merge branch feature/freemodbus_move_rs485_mode_control
Update after review:
The stack modbus folder updated to support master and slave ports together and moved into freemodbus/modbus
Stack and port files updated to remove duplicated simbols
Make file, KConfig and CMakeLists.txt updated to compile master and slave stacks, common interface and concrete implementations of ports
Stack callback functions execute callbacks using interface pointer from concrete port implementation
User can instantiate any of concrete port using common API (only one concrete port at a time) and it does not require to select port by KConfig
Port pins and mode configuration moved into example files from port files to allow user select pins and port mode (customer request)
Changes tested using pymodbus, ModbusPoll and communication between two boards
Updated DoxyFile according to public include path
Fix maximum instance size for slave (merge from master of customer issue)
Fix critical section issue TW#28622 (change spin lock based critical section to semaphore)
Move serial port files into component port folder for master and slave accordingly
Fix example issue showed in the log when IO slave is not configured correctly
Fix conflicts while merging from origin/master
Fix errors handling in modbus controller interface + some final corrections according to review
Update maximum allowed number of slaves in the network segment
Fix bug with incorrect coils read mask
Closes https://github.com/espressif/esp-idf/issues/858
Update freemodbus component file esp-idf/components/freemodbus/port/portserial.c to remove UART mode settings;
Move UART mode settings into esp-idf/examples/protocols/modbus_slave/main/freemodbus.c
Move UART pin settings from Component config into example Kconfig.projbuild file
Move setup of UART port pins from freemodbus component into example file
TW#27721
Closes https://github.com/espressif/esp-idf/issues/2784#issuecomment-443600157
This example adds functionality to support basic communication in RS485 networks using Modbus protocol.
This example uses FreeModbus stack and regular UART driver API to communicate in RS485 half duplex mode.
Added initial support of modbus controller pure C api to access device parameters over Modbus transport.
Move freemodbus stack and port files into components folder
Move the modbus_controller interface into components idf folder
Source files updated after review.
Add modbus interface documentation docs/en/api-reference/protocols/modbus.rst
porttimer.c: fix bug with timer1 selected in the Kconfig
Add support of cmake system (added cmake files)
Closes https://github.com/espressif/esp-idf/issues/858