GY-63_MS5611/libraries/SHT85/README.md
2022-01-17 21:15:55 +01:00

8.8 KiB
Raw Blame History

Arduino CI Arduino-lint JSON check License: MIT GitHub release

SHT85

Arduino library for the SHT85 temperature and humidity sensor.

Based upon the SHT31 library - https://github.com/RobTillaart/SHT31

Warning: to keep self-heating below 0.1°C, the SHT85 sensor should not be used for more than 10% of the time.

Description

    // TOPVIEW      SHT85
    //            +-------+
    // +-----\    | SDA 4 -----
    // | /-+  ----+ GND 3 -----
    // | +-+  ----+ +5V 2 -----
    // +-----/    | SCL 1 -----
    //            +-------+

The SHT85 sensors should work up to 1000 KHz, however during tests with an Arduino UNO it stopped between 500 - 550 KHz so to be safe I recommend not to use it above 400 KHz. Also the differences in read time becomes quite small. (max 15% gain). See output example sketch.

I2C speed read ms notes
100 KHz 5.11
150 KHz 4.79
200 KHz 4.64
250 KHz 4.56
300 KHz 4.50
350 KHz 4.47
400 KHz 4.45
450 KHz 4.43
500 KHz 4.42
550 KHz ---- fail

Compatibility

This library should also work for SHT30, SHT31 and SHT35 but this is not verified yet.

Accuracy table

SENSOR Temperature Humidity
SHT30 ~0.3° 2.0%
SHT31 ~0.3° 1.5%
SHT35 ~0.2° 1.5%
SHT85 ~0.2° 1.5%

Need to investigate if the interface is identical? If so the libraries might be merged.

An elaborated library for the SHT31 sensor can be found here https://github.com/hawesg/SHT31D_Particle_Photon_ClosedCube

Interface

Base interface

  • SHT() constructor of the base class. getType() will return 0.
  • SHT30() constructor.
  • SHT31() constructor.
  • SHT35() constructor.
  • SHT85() constructor.
  • uint8_t getType() returns numeric part of sensor type.
  • bool begin(uint8_t address, uint8_t dataPin, uint8_t clockPin) begin function for ESP8266 & ESP32; WARNING: not verified yet returns false if device address is incorrect or device cannot be reset.
  • bool begin(uint8_t dataPin, uint8_t clockPin) same as above. Uses SHT_DEFAULT_ADDRESS as address.
  • bool begin(uint8_t address, TwoWire *wire = &Wire) for platforms with multiple I2C buses. Default Wire as I2C bus.
  • bool begin(TwoWire *wire = &Wire) same as above. Uses SHT_DEFAULT_ADDRESS as address.
  • bool read(bool fast = true) blocks 4 (fast) or 15 (slow) milliseconds + actual read + math. Does read both the temperature and humidity.
  • bool isConnected() check sensor is reachable over I2C. Returns false if not connected.
  • uint16_t readStatus() details see datasheet and Status fields below.
  • uint32_t lastRead() in milliSeconds since start of program.
  • bool reset(bool hard = false) resets the sensor, soft reset by default. Returns false if fails.
  • float getHumidity() computes the relative humidity in % based on the latest raw reading, and returns it.
  • float getTemperature() computes the temperature in °C based on the latest raw reading, and returns it.
  • float getFahrenheit() computes the temperature in °F based on the latest raw reading, and returns it.
  • uint16_t getRawHumidity() returns the raw two-byte representation of humidity directly from the sensor.
  • uint16_t getRawTemperature() returns the raw two-byte representation of temperature directly from the sensor.

Note that the temperature and humidity values are recalculated on every call to getHumidity() and getTemperature(). If you're worried about the extra cycles, you should make sure to cache these values or only request them after you've performed a new reading.

Error interface

  • int getError() returns last set error flag and clear it. Be sure to clear the error flag by calling getError() before calling any command as the error flag could be from a previous command.
Error Symbolic Description
0x00 SHT_OK no error
0x81 SHT_ERR_WRITECMD I2C write failed
0x82 SHT_ERR_READBYTES I2C read failed
0x83 SHT_ERR_HEATER_OFF Could not switch off heater
0x84 SHT_ERR_NOT_CONNECT Could not connect
0x85 SHT_ERR_CRC_TEMP CRC error in temperature
0x86 SHT_ERR_CRC_HUM CRC error in humidity
0x87 SHT_ERR_CRC_STATUS CRC error in status field
0x88 SHT_ERR_HEATER_COOLDOWN Heater need to cool down
0x89 SHT_ERR_HEATER_ON Could not switch on heater

Heater interface

WARNING: Do not use heater for long periods.

Use the heater for max 180 seconds, and let it cool down 180 seconds = 3 minutes. Version 0.3.3 and up guards the cool down time by preventing switching the heater on within 180 seconds of the last switch off. Note: this guarding is not reboot persistent.

WARNING: The user is responsible to switch the heater off manually!

The class does NOT do this automatically. Switch off the heater by directly calling heatOff() or indirectly by calling isHeaterOn().

  • void setHeatTimeout(uint8_t seconds) Set the time out of the heat cycle. This value is truncated to max 180 seconds.
  • **uint8_t getHeatTimeout
  • bool heatOn() switches heat cycle on if not already on. Returns false if fails, setting error to SHT_ERR_HEATER_COOLDOWN or to SHT_ERR_HEATER_ON.
  • bool heatOff() switches heat cycle off. Returns false if fails, setting error to SHT_ERR_HEATER_OFF.
  • bool isHeaterOn() is the sensor still in heating cycle? replaces heatUp(). Will switch the heater off if max heating time has passed.

Async interface

See async example for usage

  • bool requestData() requests a new measurement. Returns false if the request fails.
  • bool dataReady() checks if enough time has passed to read the data. (15 milliseconds)
  • bool readData(bool fast = true) fast = true skips the CRC check. Returns false if reading fails or in case of a CRC failure.

Status fields

BIT Description value notes
15 Alert pending status 0 no pending alerts
1 at least one pending alert - default
14 Reserved 0
13 Heater status 0 Heater OFF - default
1 Heater ON
12 Reserved 0
11 Humidity tracking alert 0 no alert - default
1 alert
10 Temperature tracking alert 0 no alert - default
1 alert
9-5 Reserved 00000
4 System reset detected 0 no reset since last clear status register command
1 reset detected (hard or soft reset command or supply fail) - default
3-2 Reserved 00
1 Command status 0 last command executed successfully
1 last command not processed. Invalid or failed checksum
0 Write data checksum status 0 checksum of last write correct
1 checksum of last write transfer failed

Operation

See examples.

Future

should

  • testing
    • verify working with ESP32
    • software I2C experiments
  • improve error handling / status. (all code paths)
  • add offsets for temperature and humidity.
    • like other sensors

could

  • investigate command ART (auto sampling at 4 Hz)
  • investigate command BREAK (stop auto sampling)
  • merge with other SHT sensors if possible

won't

  • create a SHT85 simulator
    • I2C slave sketch with e.g. a DHT22 sensor/
    • not within this library.