esp-idf/examples/common_components/protocol_examples_common/Kconfig.projbuild
2019-12-03 15:53:39 +08:00

173 lines
5.9 KiB
Plaintext

menu "Example Connection Configuration"
choice EXAMPLE_CONNECT_INTERFACE
prompt "Connect using"
default EXAMPLE_CONNECT_WIFI
help
Protocol examples can use Wi-Fi or Ethernet to connect to the network.
Choose which interface to use.
config EXAMPLE_CONNECT_WIFI
bool "Wi-Fi"
config EXAMPLE_CONNECT_ETHERNET
bool "Ethernet"
endchoice
if EXAMPLE_CONNECT_WIFI
config EXAMPLE_WIFI_SSID
string "WiFi SSID"
default "myssid"
help
SSID (network name) for the example to connect to.
config EXAMPLE_WIFI_PASSWORD
string "WiFi Password"
default "mypassword"
help
WiFi password (WPA or WPA2) for the example to use.
Can be left blank if the network has no security set.
endif
if EXAMPLE_CONNECT_ETHERNET
choice EXAMPLE_USE_ETHERNET
prompt "Ethernet Type"
default EXAMPLE_USE_INTERNAL_ETHERNET if IDF_TARGET_ESP32
default EXAMPLE_USE_DM9051 if !IDF_TARGET_ESP32
help
Select which kind of Ethernet will be used in the example.
config EXAMPLE_USE_INTERNAL_ETHERNET
depends on IDF_TARGET_ESP32
select ETH_USE_ESP32_EMAC
bool "Internal EMAC"
help
Select internal Ethernet MAC controller.
config EXAMPLE_USE_DM9051
bool "DM9051 Module"
select ETH_USE_SPI_ETHERNET
select ETH_SPI_ETHERNET_DM9051
help
Select external SPI-Ethernet module.
endchoice
if EXAMPLE_USE_INTERNAL_ETHERNET
choice EXAMPLE_ETH_PHY_MODEL
prompt "Ethernet PHY Device"
default EXAMPLE_ETH_PHY_IP101
help
Select the Ethernet PHY device to use in the example.
config EXAMPLE_ETH_PHY_IP101
bool "IP101"
help
IP101 is a single port 10/100 MII/RMII/TP/Fiber Fast Ethernet Transceiver.
Goto http://www.icplus.com.tw/pp-IP101G.html for more information about it.
config EXAMPLE_ETH_PHY_RTL8201
bool "RTL8201/SR8201"
help
RTL8201F/SR8201F is a single port 10/100Mb Ethernet Transceiver with auto MDIX.
Goto http://www.corechip-sz.com/productsview.asp?id=22 for more information about it.
config EXAMPLE_ETH_PHY_LAN8720
bool "LAN8720"
help
LAN8720A is a small footprint RMII 10/100 Ethernet Transceiver with HP Auto-MDIX Support.
Goto https://www.microchip.com/LAN8720A for more information about it.
config EXAMPLE_ETH_PHY_DP83848
bool "DP83848"
help
DP83848 is a single port 10/100Mb/s Ethernet Physical Layer Transceiver.
Goto http://www.ti.com/product/DP83848J for more information about it.
endchoice
config EXAMPLE_ETH_MDC_GPIO
int "SMI MDC GPIO number"
default 23
help
Set the GPIO number used by SMI MDC.
config EXAMPLE_ETH_MDIO_GPIO
int "SMI MDIO GPIO number"
default 18
help
Set the GPIO number used by SMI MDIO.
endif
if EXAMPLE_USE_DM9051
config EXAMPLE_DM9051_SPI_HOST
int "SPI Host Number"
range 0 2
default 1
help
Set the SPI host used to communicate with DM9051.
config EXAMPLE_DM9051_SCLK_GPIO
int "SPI SCLK GPIO number"
range 0 33
default 19
help
Set the GPIO number used by SPI SCLK.
config EXAMPLE_DM9051_MOSI_GPIO
int "SPI MOSI GPIO number"
range 0 33
default 23
help
Set the GPIO number used by SPI MOSI.
config EXAMPLE_DM9051_MISO_GPIO
int "SPI MISO GPIO number"
range 0 33
default 25
help
Set the GPIO number used by SPI MISO.
config EXAMPLE_DM9051_CS_GPIO
int "SPI CS GPIO number"
range 0 33
default 22
help
Set the GPIO number used by SPI CS.
config EXAMPLE_DM9051_SPI_CLOCK_MHZ
int "SPI clock speed (MHz)"
range 20 80
default 20
help
Set the clock speed (MHz) of SPI interface.
config EXAMPLE_DM9051_INT_GPIO
int "Interrupt GPIO number"
default 4
help
Set the GPIO number used by DM9051 interrupt.
endif
config EXAMPLE_ETH_PHY_RST_GPIO
int "PHY Reset GPIO number"
default 5
help
Set the GPIO number used to reset PHY chip.
Set to -1 to disable PHY chip hardware reset.
config EXAMPLE_ETH_PHY_ADDR
int "PHY Address"
range 0 31 if EXAMPLE_USE_INTERNAL_ETHERNET
range 1 1 if !EXAMPLE_USE_INTERNAL_ETHERNET
default 1
help
Set PHY address according your board schematic.
endif
config EXAMPLE_CONNECT_IPV6
bool "Obtain IPv6 link-local address"
default y
help
By default, examples will wait until IPv4 and IPv6 addresses are obtained.
Disable this option if the network does not support IPv6.
endmenu