add support of modbus master ascii rename base dir name of master and slave example to be mb_slave, mb_master to avoid conflict with sdio/slave example test add Kconfig option to enable ASCII and RTU mode separately update ASCII options + remove cast for errors added baudrate for examples into Kconfig updated magic numbers for timer timeout put ascii private definitions into one file |
||
---|---|---|
.. | ||
common_components | ||
mb_master | ||
mb_slave | ||
example_test.py | ||
README.md |
Modbus Master-Slave Example
Overview
These two projects illustrate the communication between Modbus master and slave device in the segment. Master initializes Modbus interface driver and then reads parameters from slave device in the segment. After several successful read attempts slave sets the alarm relay (end of test condition). Once master reads the alarm it stops communication and destroy driver. See README.md for each project for more information.
Wiring
The master and slave boards should be connected to each other through the RS485 interface line driver. See the connection schematic in README.md files of each example.
Configure the project
This example test requires communication mode setting for master and slave be the same and slave address set to 1.
About common_component in this example
The folder "common_components" includes definitions of parameter structures for master and slave device (share the same parameters). However, currently it is for example purpose only.
Start example test
This test requires to set TEST_FW_PATH
environment variable and other required tools and python packages.
- Build the master and slave examples in appropriate folders as described in README.md file of each example.
- Set current folder to
examples/protocols/modbus/serial/
and start the example test scriptpython example_test.py
- The script has to find two ESP32 connected boards and flash master and slave applications, checks its configuration parameters then start test.
- Once boards flashed it starts applications and captures master and slave boards output through the terminal.
- The script uses regular expressions to check correctness of initialization and quality of communication between boards over RS485 interface.