choice RTC_CLK_SRC prompt "RTC clock source" default RTC_CLK_SRC_INT_RC help Choose which clock is used as RTC clock source. - "Internal 90kHz oscillator" option provides lowest deep sleep current consumption, and does not require extra external components. However frequency stability with respect to temperature is poor, so time may drift in deep/light sleep modes. - "External 32kHz crystal" provides better frequency stability, at the expense of slightly higher (1uA) deep sleep current consumption. - "External 32kHz oscillator" allows using 32kHz clock generated by an external circuit. In this case, external clock signal must be connected to 32K_XP pin. Amplitude should be <1.2V in case of sine wave signal, and <1V in case of square wave signal. Common mode voltage should be 0.1 < Vcm < 0.5Vamp, where Vamp is the signal amplitude. - "Internal 8MHz oscillator divided by 256" option results in higher deep sleep current (by 5uA) but has better frequency stability than the internal 90kHz oscillator. It does not require external components. config RTC_CLK_SRC_INT_RC bool "Internal 90kHz RC oscillator" config RTC_CLK_SRC_EXT_CRYS bool "External 32kHz crystal" select ESP_SYSTEM_RTC_EXT_XTAL config RTC_CLK_SRC_EXT_OSC bool "External 32kHz oscillator at 32K_XN pin" select ESP_SYSTEM_RTC_EXT_OSC config RTC_CLK_SRC_INT_8MD256 bool "Internal 8MHz oscillator, divided by 256 (~32kHz)" endchoice config RTC_CLK_CAL_CYCLES int "Number of cycles for RTC_SLOW_CLK calibration" default 3000 if RTC_CLK_SRC_EXT_CRYS || RTC_CLK_SRC_EXT_OSC || RTC_CLK_SRC_INT_8MD256 default 576 if RTC_CLK_SRC_INT_RC range 0 8190 if RTC_CLK_SRC_EXT_CRYS || RTC_CLK_SRC_EXT_OSC || RTC_CLK_SRC_INT_8MD256 range 0 32766 if RTC_CLK_SRC_INT_RC help When the startup code initializes RTC_SLOW_CLK, it can perform calibration by comparing the RTC_SLOW_CLK frequency with main XTAL frequency. This option sets the number of RTC_SLOW_CLK cycles measured by the calibration routine. Higher numbers increase calibration precision, which may be important for applications which spend a lot of time in deep sleep. Lower numbers reduce startup time. When this option is set to 0, clock calibration will not be performed at startup, and approximate clock frequencies will be assumed: - 90000 Hz if internal RC oscillator is used as clock source. For this use value 1024. - 32768 Hz if the 32k crystal oscillator is used. For this use value 3000 or more. In case more value will help improve the definition of the launch of the crystal. If the crystal could not start, it will be switched to internal RC. config RTC_XTAL_CAL_RETRY int "Number of attempts to repeat 32k XTAL calibration" default 3 depends on RTC_CLK_SRC_EXT_CRYS help Number of attempts to repeat 32k XTAL calibration before giving up and switching to the internal RC. Increase this option if the 32k crystal oscillator does not start and switches to internal RC.