* Fix the issue that deinit node with "erase_flash"
set to true, but info is not erased from nvs
* Reuse bt_mesh_cfg_reset() when deinit node
* Optimize Provisioner related erase operations
* No store pending timeout will be used when Node
is not provisioned OR Provisioner is disabled
and erase operation is performed
* Change the default timeout for settings operation
to 0, and rpl store rate to 0
1. Add g_av_with_rc to avrc_tg_init function
2. Remove g_av_open_fail
3. Add comment in API files
4. Add a2dp init & deinit state variable to inidcate a2dp statement
When reset the rx info of transport layer, the
rpl list will always cleared, and rpl stored
in the nvs will only be erased when erase flag
is true and BLE_MESH_SETTINGS is enabled.
Compared with the previous solution, it should
be more clear.
1. Add reaction for a2dp snk & src disconn req when no link up
2. Change state machine set before EVT upto APP layer in some cases
3. Add bool open_fail to choose whether post disconnection evt to app layer
Provisioner should always uses the latest IV Index for provisioning.
For example, if the current IV Index is 0x00000001, but prov->iv_index
is still initialized with 0x00000000, and if Provisioner uses prov->
iv_index for provisioning, this will cause the Provisioner failing to
control the node.
So here bt_mesh.iv_index is used instead of prov->iv_index.
- Previously when a model is initialized or deinitialized, in the
access layer, we need to check the model id with the ids in the
table in order to find the proper model operation function.
- Currently all the operation functions of each model will be set
during the mesh initialization. When the model is found, we can
directly use the corresponding callback for different operations.
- Currently only init/deinit operations are registered, later we
will add more operations.
* changing dependencies from unity->cmock
* added component.mk and Makefile.projbuild
* ignore test dir in gen_esp_err_to_name.py
* added some brief introduction of CMock in IDF
1. Add logs for SPP not enabled successfully
2. Add information to Applicatioin layer that the A2DP is connecting to peer device
Regular BTC and BTU Task name & Add BTC Init protection
1. Regular the BTC Task Name to Close a Github issue
Closes https://github.com/espressif/esp-idf/issues/4966
2. Add BTC Init failure protection
3. Regular BTU Task Name with BTC
4. Correct the comment of
a. SDP_ServiceSearchRequest and SDP_ServiceSearchRequest2
b. l2cu_create_conn_after_switch
5. Correct comment of esp_bt_hf_vra();
6. Fix cpp compilier region