1. BLE only with 9(max) connection will decrease 3K DRAM
2. BR/EDR only with 7(max) connection will decrease 16K DRAM
3. Any of BLE or BR/EDR connection number decrease will also decrease DRAM consumption
4. Decrease one BLE connection will save about 1KB DRAM
5. Decrease one BR/EDR ACL connection will save about 1.2KB DRAM
6. Decrease one BR/EDR SCO/eSCO will save 2KB DRAM.
7. fix some definition and kconfig
8. remove 1.2k of vhci tx cache and make .bss & .data to heap about 1.4K
9. modify BT Reserved Memory size and modify example to support new bt kconfig
This change adds a check for compatibility between the nvs version
found on nvs flash and the one assumed by running code during nvs
initialization. Any mismatch is reported to the user using new error
code ESP_ERR_NVS_NEW_VERSION_FOUND.
Earlier they have to be selected at the compile time through sdkconfig.
A2DP sink and source application tested with this change.
Signed-off-by: Amey Inamdar <amey@espressif.com>