Commit Graph

3 Commits

Author SHA1 Message Date
morris
a7021c3e44 mcpwm: fix bldc example force output level inverted
set_force_level can only set the generator level before the deadtime module.
if the deadtime module enables the inverter, then the real output level is inverted accordingly
2023-05-12 14:40:10 +08:00
morris
7b93cf91aa mcpwm: can't apply the same delay module to multiple generators
This is a hardware limitation, one delay module can only be used by one generator at one time.

Closes https://github.com/espressif/esp-idf/issues/11327
2023-05-10 10:09:48 +08:00
laokaiyao