Commit Graph

14 Commits

Author SHA1 Message Date
gaoxu
f2f2de1a66 fix(adc): fix adc continuous get less results beacuse do not reset apb clk(v4.4) 2023-12-04 15:02:18 +08:00
Armando
b282c244cb DMA EOF may happens per multiple dma descriptors, instead of only one.
Closes https://github.com/espressif/esp-idf/pull/11500
2023-09-05 11:18:56 +08:00
Armando
85ce6abdec Fix #10804 by running continuous ADC DMA in endless loop instead of restarting after each run (descriptor chain) to avoid losing samples. Use descriptor error callback for GDMA to check for DMA buffer overrun. 2023-09-05 11:18:56 +08:00
Armando
91da3bcdc1 adc: fix adc continuous driver conv_frame_size not bigger than 4092 issue 2023-09-05 11:18:52 +08:00
Armando
1b2a254d71 adc: improve power logic 2023-04-20 10:42:12 +08:00
morris
6e950ad679 Merge branch 'bugfix/adc2_legacy_oneshot_clk_gating_issue' into 'release/v4.4'
adc: fix legacy oneshot driver clock gating issue on c3 (v4.4)

See merge request espressif/esp-idf!22609
2023-03-09 13:29:40 +08:00
Armando
eab3534c90 adc: no longer support adc2 oneshot mode on esp32c3
Due to HW limitation, we don't support this anymore. On c3, ADC2 under oneshot mode is not stable.

However, you can enable CONFIG_ADC_ONESHOT_FORCE_USE_ADC2_ON_C3 to force use
ADC2.

Refer to errata to know more details:
https://www.espressif.com/sites/default/files/documentation/esp32-c3_errata_en.pdf
2023-03-07 11:58:27 +08:00
Armando
f0af48b585 adc: fix legacy oneshot driver clock gating issue on c3 2023-03-07 02:39:11 +00:00
Armando
ffb2db586a adc: no longer support adc2 continuous mode on esp32c3 and esp32s3
Due to HW limitation, we don't support this anymore. On s3 and c3, ADC2 under continuous  mode is not stable.

However, you can enable CONFIG_ADC_CONTINUOUS_FORCE_USE_ADC2_ON_C3_S3 to force use
ADC2.

Refer to errata to know more details:
https://www.espressif.com/sites/default/files/documentation/esp32-s3_errata_en.pdf
https://www.espressif.com/sites/default/files/documentation/esp32-c3_errata_en.pdf
2023-03-06 18:57:58 +08:00
Armando
ad8862fa19 adc: fix esp32s2 continuous mode converted bytes issue
When working in continuous mode, hardware will continuously trigger
ADC to do conversions. On esp32s2, 2 bytes will be generated per
conversion. Prior to this commit, driver assumes 4 bytes per conversion
(on s2). This commit fixed this issue.
2022-07-20 16:43:38 +08:00
Armando
e1515beb26 adc: fix adc digital not reset issue 2022-03-07 11:40:18 +08:00
Armando
1ec46ad3b8 adc: support adc dma driver on all chips 2021-12-23 17:13:46 +08:00
fuzhibo
baa7898e35 driver(adc/dac): fix adc dac driver for esp32s2
1. update register file about adc; 2. fix adc driver; 3. add UT for adc/dac;

See merge request espressif/esp-idf!7776
2020-04-01 12:41:51 +08:00
fuzhibo
f49b192a5e refactor the adc driver 2019-11-22 15:42:16 +08:00