fix(bt/example): Fixed UART HCI when flow control is off on ESP32C3

This commit is contained in:
chenjianhua 2023-12-06 15:26:42 +08:00
parent 4ddb8587d9
commit 730537b50c

View File

@ -31,12 +31,6 @@ static const char *tag = "UHCI";
#define GPIO_OUTPUT_PIN_SEL ((1ULL<<GPIO_UART_TXD_OUT) | (1ULL<<GPIO_UART_RTS_OUT))
#define GPIO_INPUT_PIN_SEL ((1ULL<<GPIO_UART_RXD_IN) | (1ULL<<GPIO_UART_CTS_IN))
#ifdef CONFIG_EXAMPLE_HCI_UART_FLOW_CTRL_ENABLE
#define HCI_UART_FLOW_CTRL_ENABLE CONFIG_EXAMPLE_HCI_UART_FLOW_CTRL_ENABLE
#else
#define HCI_UART_FLOW_CTRL_ENABLE FALSE
#endif
// Operation functions for HCI UART Transport Layer
static bool hci_uart_tl_init(void);
static void hci_uart_tl_deinit(void);
@ -211,7 +205,7 @@ void uhci_uart_install(void)
.data_bits = UART_DATA_8_BITS,
.parity = UART_PARITY_DISABLE,
.stop_bits = UART_STOP_BITS_1,
#if (HCI_UART_FLOW_CTRL_ENABLE == TRUE)
#ifdef CONFIG_EXAMPLE_HCI_UART_FLOW_CTRL_ENABLE
.flow_ctrl = UART_HW_FLOWCTRL_CTS_RTS,
#else
.flow_ctrl = UART_HW_FLOWCTRL_DISABLE,