ble_mesh: Not ignore msg when fast prov is enabled

When fast provisioning is enabled, Provisioner shall not
ignore messages from the nodes whose addresses are not in
the provisioning database. Because other nodes which are
not provisioned by the Primary Provisioner will send node
address messages to the Primary Provisioner.
This commit is contained in:
lly 2020-05-12 11:21:57 +08:00
parent 44d1c90d25
commit 4748b07fa2

View File

@ -1399,6 +1399,14 @@ static bool ready_to_recv(void)
static bool ignore_net_msg(u16_t src, u16_t dst)
{
if (IS_ENABLED(CONFIG_BLE_MESH_FAST_PROV)) {
/* When fast provisioning is enabled, the node addr
* message will be sent to the Primary Provisioner,
* which shall not be ignored here.
*/
return false;
}
if (IS_ENABLED(CONFIG_BLE_MESH_PROVISIONER) &&
bt_mesh_is_provisioner_en() &&
BLE_MESH_ADDR_IS_UNICAST(dst) &&
@ -1409,6 +1417,7 @@ static bool ignore_net_msg(u16_t src, u16_t dst)
* be ignored.
*/
if (!bt_mesh_provisioner_get_node_with_addr(src)) {
BT_INFO("Not found node address 0x%04x", src);
return true;
}
}