Fix bug that when we do full calibration init data bin is not used
This commit is contained in:
parent
eb659e401d
commit
11c0daef62
@ -940,13 +940,18 @@ endmenu # Wi-Fi
|
||||
menu PHY
|
||||
|
||||
config ESP32_PHY_CALIBRATION_AND_DATA_STORAGE
|
||||
bool "Do phy calibration and store calibration data in NVS"
|
||||
bool "Store phy calibration data in NVS"
|
||||
default y
|
||||
help
|
||||
If this option is enabled, NVS will be initialized and calibration data will be loaded from there.
|
||||
PHY calibration will be skipped on deep sleep wakeup. If calibration data is not found, full calibration
|
||||
will be performed and stored in NVS. In all other cases, only partial calibration will be performed.
|
||||
will be performed and stored in NVS. Normally, only partial calibration will be performed.
|
||||
If this option is disabled, full calibration will be performed.
|
||||
|
||||
If it's easy that your board calibrate bad data, choose 'n'.
|
||||
Two cases for example, you should choose 'n':
|
||||
1.If your board is easy to be booted up with antenna disconnected.
|
||||
2.Because of your board design, each time when you do calibration, the result are too unstable.
|
||||
If unsure, choose 'y'.
|
||||
|
||||
config ESP32_PHY_INIT_DATA_IN_PARTITION
|
||||
|
@ -266,17 +266,17 @@ void esp_phy_load_cal_and_init(void)
|
||||
abort();
|
||||
}
|
||||
|
||||
#ifdef CONFIG_ESP32_PHY_CALIBRATION_AND_DATA_STORAGE
|
||||
esp_phy_calibration_mode_t calibration_mode = PHY_RF_CAL_PARTIAL;
|
||||
if (rtc_get_reset_reason(0) == DEEPSLEEP_RESET) {
|
||||
calibration_mode = PHY_RF_CAL_NONE;
|
||||
}
|
||||
const esp_phy_init_data_t* init_data = esp_phy_get_init_data();
|
||||
if (init_data == NULL) {
|
||||
ESP_LOGE(TAG, "failed to obtain PHY init data");
|
||||
abort();
|
||||
}
|
||||
|
||||
#ifdef CONFIG_ESP32_PHY_CALIBRATION_AND_DATA_STORAGE
|
||||
esp_phy_calibration_mode_t calibration_mode = PHY_RF_CAL_PARTIAL;
|
||||
if (rtc_get_reset_reason(0) == DEEPSLEEP_RESET) {
|
||||
calibration_mode = PHY_RF_CAL_NONE;
|
||||
}
|
||||
esp_err_t err = esp_phy_load_cal_data_from_nvs(cal_data);
|
||||
if (err != ESP_OK) {
|
||||
ESP_LOGW(TAG, "failed to load RF calibration data (0x%x), falling back to full calibration", err);
|
||||
@ -290,11 +290,12 @@ void esp_phy_load_cal_and_init(void)
|
||||
} else {
|
||||
err = ESP_OK;
|
||||
}
|
||||
esp_phy_release_init_data(init_data);
|
||||
#else
|
||||
esp_phy_rf_init(NULL, PHY_RF_CAL_FULL, cal_data);
|
||||
esp_phy_rf_init(init_data, PHY_RF_CAL_FULL, cal_data);
|
||||
#endif
|
||||
|
||||
esp_phy_release_init_data(init_data);
|
||||
|
||||
free(cal_data); // PHY maintains a copy of calibration data, so we can free this
|
||||
}
|
||||
|
||||
|