2017-12-04 07:05:09 -05:00
|
|
|
ESP SDIO slave protocol
|
|
|
|
=======================
|
|
|
|
|
|
|
|
The protocol is based on Function 1 access by CMD52 and CMD53, offering 3 services: (1) sending and receiving FIFO, (2) 52 8-bit R/W
|
|
|
|
register shared by host and slave, (3) 8 general purpose interrupt sources from host to slave and 8 in the oppsite direction.
|
|
|
|
|
|
|
|
The host should access the registers below as described to communicate with slave.
|
|
|
|
|
|
|
|
Slave register table
|
|
|
|
--------------------
|
|
|
|
|
|
|
|
32-bit
|
|
|
|
^^^^^^^
|
|
|
|
- 0x044 (TOKEN_RDATA): in which bit 27-16 holds the receiving buffer number.
|
|
|
|
- 0x058 (INT_ST): holds the interrupt source bits from slave to host.
|
|
|
|
- 0x060 (PKT_LEN): holds the accumulated length (by byte) to be sent from slave to host.
|
|
|
|
- 0x0D4 (INT_CLR): write 1 to clear interrupt bits corresponding to INT_ST.
|
|
|
|
- 0x0DC (INT_ENA): mask bits for interrupts from slave to host.
|
|
|
|
|
|
|
|
8-bit
|
|
|
|
^^^^^
|
|
|
|
Shared general purpose registers:
|
|
|
|
|
|
|
|
- 0x06C-0x077: R/W registers 0-11 shared by slave and host.
|
|
|
|
- 0x07A-0x07B: R/W registers 14-15 shared by slave and host.
|
|
|
|
- 0x07E-0x07F: R/W registers 18-19 shared by slave and host.
|
|
|
|
- 0x088-0x08B: R/W registers 24-27 shared by slave and host.
|
|
|
|
- 0x09C-0x0BB: R/W registers 32-63 shared by slave and host.
|
|
|
|
|
|
|
|
Interrupt Registers:
|
|
|
|
- 0x08D (SLAVE_INT): bits for host to interrupt slave. auto clear.
|
|
|
|
|
|
|
|
FIFO (sending and receiving)
|
|
|
|
^^^^^^^^^^^^^^^^^^^^^^^^^^^^
|
|
|
|
|
|
|
|
0x090 - 0x1F7FF are reserved for FIFOs.
|
|
|
|
|
2018-06-22 04:21:03 -04:00
|
|
|
The address of CMD53 is related to the length requested to read from/write to
|
|
|
|
the slave in a single transfer:
|
|
|
|
|
|
|
|
*requested length = 0x1F800-address*
|
|
|
|
|
|
|
|
The slave will respond with the length according to the length field in
|
|
|
|
CMD53, with the data longer than *requested length* filled with 0 (sending)
|
|
|
|
or discard (receiving).
|
|
|
|
|
|
|
|
.. note:: This includes both the block and the byte mode of CMD53.
|
2017-12-04 07:05:09 -05:00
|
|
|
|
|
|
|
The function number should be set to 1, OP Code should be set to 1 (for CMD53).
|
|
|
|
|
2018-06-22 04:21:03 -04:00
|
|
|
It is allowed to use CMD53 mode combination of block+byte to get higher
|
|
|
|
effeciency when accessing the FIFO by arbitrary length. E.g. The block
|
|
|
|
size is set to 512 by default, you can write/get 1031 bytes of data
|
|
|
|
to/from the FIFO by:
|
|
|
|
|
|
|
|
1. Send CMD53 in block mode, block count=2 (1024 bytes) to address
|
|
|
|
0x1F3F9=0x1F800-**1031**.
|
|
|
|
2. Then send CMD53 in byte mode, byte count=8 (or 7 if your controller
|
|
|
|
supports that) to address 0x1F7F9=0x1F800-**7**.
|
2017-12-04 07:05:09 -05:00
|
|
|
|
|
|
|
Interrupts
|
|
|
|
----------
|
|
|
|
|
|
|
|
For the host interrupts, the slave raise the interrupt by pulling DAT1 line down at a proper time (level sensitive).
|
|
|
|
The host detect this and read the INT_ST register to see the source. Then the host can clear it by writing the INT_CLR
|
|
|
|
register and do something with the interrupt. The host can also mask unneeded sources by clearing the bits in INT_ENA
|
|
|
|
register corresponding to the sources. If all the sources are cleared (or masked), the DAT1 line goes inactive.
|
|
|
|
|
|
|
|
``sdio_slave_hostint_t`` (:doc:`sdio_slave`) shows the bit definition corresponding to host interrupt sources.
|
|
|
|
|
|
|
|
For the slave interrupts, the host send transfers to write the SLAVE_INT register. Once a bit is written from 0 to 1,
|
|
|
|
the slave hardware and driver will detect it and inform the app.
|
|
|
|
|
|
|
|
Receiving FIFO
|
|
|
|
--------------
|
|
|
|
|
|
|
|
To write the receiving FIFO in the slave, host should work in the following steps:
|
|
|
|
|
|
|
|
1. Read the TOKEN1 field (bits 27-16) of TOKEN_RDATA (0x044) register. The buffer number remaining is TOKEN1 minus
|
|
|
|
the number of buffers used by host.
|
|
|
|
2. Make sure the buffer number is sufficient (*buffer_size* * *buffer_num* is greater than data to write, *buffer_size*
|
|
|
|
is pre-defined between the host and the slave before the communication starts). Or go back to step 1 until the buffer
|
|
|
|
is enough.
|
|
|
|
3. Write to the FIFO address with CMD53. Note that the *requested length* should not be larger than calculated in step 2,
|
|
|
|
and the FIFO address is related to *rquested length*.
|
|
|
|
4. Calculate used buffers, note that non-full buffer at the tail should be seen as one that is used.
|
|
|
|
|
|
|
|
Sending FIFO
|
|
|
|
------------
|
|
|
|
|
|
|
|
To read the sending FIFO in the slave, host should work in the following steps:
|
|
|
|
|
|
|
|
1. Wait for the interrupt line to be active (optional, low by default).
|
|
|
|
2. Read (poll) the interrupt bits in INT_ST register to see whether new packets exists.
|
|
|
|
3. If new packets are ready, reads the PKT_LEN reg. The data length to read from slave is PKT_LEN minuses the length
|
|
|
|
that has been read from the host. If the PKT_LEN is not larger than used, wait and poll until the slave is ready and
|
|
|
|
update the PKT_LEN.
|
|
|
|
4. Read from the FIFO with CMD53. Note that the *requested length* should not be larger than calculated in step3, and
|
|
|
|
the FIFO address is related to *requested length*.
|
|
|
|
5. Recored read length.
|
|
|
|
|