esp-idf/examples/protocols/modbus/serial/mb_master/main/Kconfig.projbuild

80 lines
2.7 KiB
Plaintext
Raw Normal View History

menu "Modbus Example Configuration"
orsource "$IDF_PATH/examples/common_components/env_caps/$IDF_TARGET/Kconfig.env_caps"
config MB_UART_PORT_ONE
bool
default y
depends on (ESP_CONSOLE_UART_NUM !=1) && (SOC_UART_NUM > 1)
config MB_UART_PORT_TWO
bool
default y
depends on (ESP_CONSOLE_UART_NUM !=2) && (SOC_UART_NUM > 2)
config MB_UART_PORT_NUM
int "UART port number"
range 0 2 if MB_UART_PORT_TWO
default 2 if MB_UART_PORT_TWO
range 0 1 if MB_UART_PORT_ONE
default 1 if MB_UART_PORT_ONE
help
UART communication port number for Modbus example.
config MB_UART_BAUD_RATE
int "UART communication speed"
range 1200 115200
default 115200
help
UART communication speed for Modbus example.
config MB_UART_RXD
int "UART RXD pin number"
range ENV_GPIO_RANGE_MIN ENV_GPIO_IN_RANGE_MAX
default 22 if IDF_TARGET_ESP32 || IDF_TARGET_ESP32C6
default 8 if IDF_TARGET_ESP32S2 || IDF_TARGET_ESP32S3 || IDF_TARGET_ESP32C3 ||\
IDF_TARGET_ESP32C2 || IDF_TARGET_ESP32H2
help
GPIO number for UART RX pin. See UART documentation for more information
about available pin numbers for UART.
config MB_UART_TXD
int "UART TXD pin number"
range ENV_GPIO_RANGE_MIN ENV_GPIO_OUT_RANGE_MAX
default 23 if IDF_TARGET_ESP32 || IDF_TARGET_ESP32C6
default 9 if IDF_TARGET_ESP32S2 || IDF_TARGET_ESP32S3 || IDF_TARGET_ESP32C3 ||\
IDF_TARGET_ESP32C2 || IDF_TARGET_ESP32H2
help
GPIO number for UART TX pin. See UART documentation for more information
about available pin numbers for UART.
config MB_UART_RTS
int "UART RTS pin number"
range ENV_GPIO_RANGE_MIN ENV_GPIO_OUT_RANGE_MAX
default 18 if IDF_TARGET_ESP32 || IDF_TARGET_ESP32C6
default 10 if IDF_TARGET_ESP32S2 || IDF_TARGET_ESP32S3 || IDF_TARGET_ESP32C3 ||\
IDF_TARGET_ESP32C2 || IDF_TARGET_ESP32H2
help
GPIO number for UART RTS pin. This pin is connected to
~RE/DE pin of RS485 transceiver to switch direction.
See UART documentation for more information about available pin
numbers for UART.
choice MB_COMM_MODE
prompt "Modbus communication mode"
default MB_COMM_MODE_RTU if CONFIG_FMB_COMM_MODE_RTU_EN
help
Selection of Modbus communication mode option for Modbus.
config MB_COMM_MODE_RTU
bool "RTU mode"
depends on FMB_COMM_MODE_RTU_EN
config MB_COMM_MODE_ASCII
bool "ASCII mode"
depends on FMB_COMM_MODE_ASCII_EN
endchoice
endmenu