esp-idf/examples/system/ota/advanced_https_ota/main/Kconfig.projbuild

46 lines
1.5 KiB
Plaintext
Raw Normal View History

menu "Example Configuration"
2019-05-09 10:43:06 -04:00
config EXAMPLE_FIRMWARE_UPGRADE_URL
string "Firmware Upgrade URL"
default "https://192.168.2.106:8070/hello_world.bin"
help
URL of server which hosts the firmware image.
config EXAMPLE_FIRMWARE_UPGRADE_URL_FROM_STDIN
bool
default y if EXAMPLE_FIRMWARE_UPGRADE_URL = "FROM_STDIN"
config EXAMPLE_SKIP_COMMON_NAME_CHECK
bool "Skip server certificate CN fieldcheck"
default n
help
This allows you to skip the validation of OTA server certificate CN field.
config EXAMPLE_SKIP_VERSION_CHECK
bool "Skip firmware version check"
default n
help
This allows you to skip the firmware version check.
config EXAMPLE_OTA_RECV_TIMEOUT
int "OTA Receive Timeout"
default 5000
help
Maximum time for reception
config EXAMPLE_ENABLE_PARTIAL_HTTP_DOWNLOAD
bool "Enable partial HTTP download"
default n
help
This enables use of Range header in esp_https_ota component.
Firmware image will be downloaded over multiple HTTP requests.
config EXAMPLE_HTTP_REQUEST_SIZE
int "HTTP request size"
default MBEDTLS_SSL_IN_CONTENT_LEN
depends on EXAMPLE_ENABLE_PARTIAL_HTTP_DOWNLOAD
help
This options specifies HTTP request size. Number of bytes specified
in this option will be downloaded in single HTTP request.
endmenu