mirror of
https://github.com/RobTillaart/Arduino.git
synced 2024-10-03 18:09:02 -04:00
156 lines
7.4 KiB
Markdown
156 lines
7.4 KiB
Markdown
|
||
[![Arduino CI](https://github.com/robtillaart/SHT31/workflows/Arduino%20CI/badge.svg)](https://github.com/marketplace/actions/arduino_ci)
|
||
[![JSON check](https://github.com/RobTillaart/SHT31/actions/workflows/jsoncheck.yml/badge.svg)](https://github.com/RobTillaart/SHT31/actions/workflows/jsoncheck.yml)
|
||
[![Arduino-lint](https://github.com/RobTillaart/SHT31/actions/workflows/arduino-lint.yml/badge.svg)](https://github.com/RobTillaart/SHT31/actions/workflows/arduino-lint.yml)
|
||
[![License: MIT](https://img.shields.io/badge/license-MIT-green.svg)](https://github.com/RobTillaart/SHT31/blob/master/LICENSE)
|
||
[![GitHub release](https://img.shields.io/github/release/RobTillaart/SHT31.svg?maxAge=3600)](https://github.com/RobTillaart/SHT31/releases)
|
||
|
||
|
||
# SHT31
|
||
|
||
Arduino library for the SHT31 temperature and humidity sensor.
|
||
|
||
Relates to the SHT85 library - https://github.com/RobTillaart/SHT85
|
||
|
||
|
||
## Description
|
||
|
||
The SHT3x family of sensors should work up to 1 MHz I2C
|
||
|
||
This library should also work for SHT30 and SHT35 but these are
|
||
not tested yet.
|
||
|
||
Accuracy table
|
||
|
||
| SENSOR | Temperature | Humidity |
|
||
|:--------:|:-------------:|:----------:|
|
||
| SHT30 | ~0.3 | 2.0 |
|
||
| SHT31 | ~0.3 | 1.5 |
|
||
| SHT35 | ~0.2 | 1.5 |
|
||
| SHT85 | ~0.2 | 1.5 |
|
||
|
||
|
||
An elaborated library for the SHT31 sensor can be found here
|
||
https://github.com/hawesg/SHT31D_Particle_Photon_ClosedCube
|
||
|
||
|
||
## Interface
|
||
|
||
#### Base interface
|
||
|
||
- **SHT31()** constructor.
|
||
- **bool begin(uint8_t address, uint8_t dataPin, uint8_t clockPin)** begin function for ESP8266 & ESP32;
|
||
returns false if device address is incorrect or device cannot be reset.
|
||
- **bool begin(uint8_t dataPin, uint8_t clockPin)** same as above. With default SHT_DEFAULT_ADDRESS.
|
||
- **bool begin(uint8_t address, TwoWire \*wire = &Wire)** for platforms with multiple I2C buses.
|
||
- **bool begin(TwoWire \*wire = &Wire)** same as above.
|
||
With default SHT_DEFAULT_ADDRESS.
|
||
- **bool read(bool fast = true)** blocks 4 (fast) or 15 (slow) milliseconds + actual read + math.
|
||
Does read both the temperature and humidity.
|
||
- **bool isConnected()** check sensor is reachable over I2C. Returns false if not connected.
|
||
- **uint16_t readStatus()** details see datasheet and **Status fields** below.
|
||
- **uint32_t lastRead()** in milliSeconds since start of program.
|
||
- **bool reset(bool hard = false)** resets the sensor, soft reset by default. Returns false if it fails.
|
||
- **float getHumidity()** computes the relative humidity in % based on the latest raw reading, and returns it.
|
||
- **float getTemperature()** computes the temperature in <20>C based on the latest raw reading, and returns it.
|
||
- **float getFahrenheit()** computes the temperature in <20>F based on the latest raw reading, and returns it..
|
||
- **uint16_t getRawHumidity()** returns the raw two-byte representation of humidity directly from the sensor.
|
||
- **uint16_t getRawTemperature()** returns the raw two-byte representation of temperature directly from the sensor.
|
||
|
||
Note that the temperature and humidity values are recalculated on every call to getHumidity() and getTemperature().
|
||
If you're worried about the extra cycles, you should make sure to cache these values or only request them after
|
||
you've performed a new reading.
|
||
|
||
|
||
#### Error interface
|
||
|
||
- **int getError()** returns last set error flag and clear it.
|
||
Be sure to clear the error flag by calling **getError()** before calling any command as the error flag could be from a previous command.
|
||
|
||
| Error | Symbolic | Description |
|
||
|:-------:|:----------------------------|:------------------------------|
|
||
| 0x00 | SHT31_OK | no error |
|
||
| 0x81 | SHT31_ERR_WRITECMD | I2C write failed |
|
||
| 0x82 | SHT31_ERR_READBYTES | I2C read failed |
|
||
| 0x83 | SHT31_ERR_HEATER_OFF | Could not switch off heater |
|
||
| 0x84 | SHT31_ERR_NOT_CONNECT | Could not connect |
|
||
| 0x85 | SHT31_ERR_CRC_TEMP | CRC error in temperature |
|
||
| 0x86 | SHT31_ERR_CRC_HUM | CRC error in humidity |
|
||
| 0x87 | SHT31_ERR_CRC_STATUS | CRC error in status field |
|
||
| 0x88 | SHT31_ERR_HEATER_COOLDOWN | Heater need to cool down |
|
||
| 0x88 | SHT31_ERR_HEATER_ON | Could not switch on heater |
|
||
|
||
|
||
#### Heater interface
|
||
|
||
**WARNING:** Do not use heater for long periods.
|
||
|
||
Use the heater for max **180** seconds, and let it cool down **180** seconds = 3 minutes.
|
||
Version 0.3.3 and up guards the cool down time by preventing switching the heater on
|
||
within **180** seconds of the last switch off. Note: this guarding is not reboot persistent.
|
||
|
||
**WARNING:** The user is responsible to switch the heater off manually!
|
||
|
||
The class does **NOT** do this automatically.
|
||
Switch off the heater by directly calling **heatOff()** or indirectly by calling **isHeaterOn()**.
|
||
|
||
- **void setHeatTimeout(uint8_t seconds)** Set the time out of the heat cycle.
|
||
This value is truncated to max 180 seconds.
|
||
- **uint8_t getHeatTimeout
|
||
- **bool heatOn()** switches heat cycle on if not already on.
|
||
Returns false if fails, setting error to **SHT31_ERR_HEATER_COOLDOWN**
|
||
or to **SHT31_ERR_HEATER_ON**.
|
||
- **bool heatOff()** switches heat cycle off.
|
||
Returns false if fails, setting error to **SHT31_ERR_HEATER_OFF**.
|
||
- **bool isHeaterOn()** is the sensor still in heating cycle? replaces **heatUp()**.
|
||
Will switch the heater off if max heating time has passed.
|
||
- **bool heatUp()** will be obsolete in the future. replaced by **isHeaterOn()**
|
||
|
||
|
||
#### Async interface
|
||
|
||
See async example for usage
|
||
|
||
- **bool requestData()** requests a new measurement. Returns false if this fails.
|
||
- **bool dataReady()** checks if enough time has passed to read the data. (15 milliseconds)
|
||
- **bool readData(bool fast = true)** fast = true skips the CRC check.
|
||
Returns false if reading fails or in case of a CRC failure.
|
||
|
||
|
||
## Status fields
|
||
|
||
| BIT | Description | value | notes |
|
||
|:------|:-----------------------------|:--------|:--------|
|
||
| 15 | Alert pending status | 0 | no pending alerts
|
||
| | | 1 | at least one pending alert - default
|
||
| 14 | Reserved | 0 |
|
||
| 13 | Heater status | 0 | Heater OFF - default
|
||
| | | 1 | Heater ON
|
||
| 12 | Reserved | 0 |
|
||
| 11 | Humidity tracking alert | 0 | no alert - default
|
||
| | | 1 | alert
|
||
| 10 | Temperature tracking alert | 0 | no alert - default
|
||
| | | 1 | alert
|
||
| 9-5 | Reserved | 00000 |
|
||
| 4 | System reset detected | 0 | no reset since last <20>clear status register<65> command
|
||
| | | 1 | reset detected (hard or soft reset command or supply fail) - default
|
||
| 3-2 | Reserved | 00 |
|
||
| 1 | Command status | 0 | last command executed successfully
|
||
| | | 1 | last command not processed. Invalid or failed checksum
|
||
| 0 | Write data checksum status | 0 | checksum of last write correct
|
||
| | | 1 | checksum of last write transfer failed
|
||
|
||
|
||
|
||
## Operation
|
||
|
||
See examples.
|
||
|
||
|
||
## Future
|
||
|
||
- keep in sync with SHT85 library
|
||
- check TODO in code
|
||
|
||
|