GY-63_MS5611/libraries/AS5600
2024-02-10 13:23:53 +01:00
..
.github 0.3.5 AS5600 2023-02-01 16:57:56 +01:00
examples 0.6.0 AS5600 2024-02-10 13:23:53 +01:00
test 0.5.1 AS5600 2024-01-05 09:44:05 +01:00
.arduino-ci.yml 0.3.2 AS5600 2022-10-17 09:48:27 +02:00
AS5600.cpp 0.6.0 AS5600 2024-02-10 13:23:53 +01:00
AS5600.h 0.6.0 AS5600 2024-02-10 13:23:53 +01:00
CHANGELOG.md 0.6.0 AS5600 2024-02-10 13:23:53 +01:00
keywords.txt 0.6.0 AS5600 2024-02-10 13:23:53 +01:00
library.json 0.6.0 AS5600 2024-02-10 13:23:53 +01:00
library.properties 0.6.0 AS5600 2024-02-10 13:23:53 +01:00
LICENSE 0.5.1 AS5600 2024-01-05 09:44:05 +01:00
README.md 0.6.0 AS5600 2024-02-10 13:23:53 +01:00

Arduino CI Arduino-lint JSON check GitHub issues

License: MIT GitHub release PlatformIO Registry

AS5600

Arduino library for AS5600 and AS5600L magnetic rotation meter.

Description

AS5600

AS5600 is a library for an AS5600 / AS5600L based magnetic rotation meter. More exact, it measures the angle (rotation w.r.t. reference) and not RPM. Multiple angle measurements allows one to calculate / estimate the RPM.

The AS5600 and AS5600L sensors are pin compatible (always check datasheet).

Warning: experimental

The sensor can measure a full rotation in 4096 steps. The precision of the position is therefore limited to approx 0.1°. Noise levels are unknown, but one might expect that the sensor is affected by electric and or magnetic signals in the environment. Also unknown is the influence of metals near the sensor or an unstable or fluctuating power supply.

Please share your experiences.

0.5.0 Breaking change

Version 0.5.0 introduced a breaking change. You cannot set the pins in begin() any more. This reduces the dependency of processor dependent Wire implementations. The user has to call Wire.begin() and can optionally set the Wire pins before calling begin().

Hardware connection

The I2C address of the AS5600 is always 0x36.

The sensor should connect the I2C lines SDA and SCL and the VCC and GND to communicate with the processor. Do not forget to add the pull up resistors to improve the I2C signals.

The AS5600 datasheet states it supports Fast-Mode == 400 KHz and Fast-Mode-Plus == 1000 KHz.

Pull ups

I2C performance tests with an AS5600L with an UNO failed at 400 KHz. After investigation it became clear that pull ups are mandatory. The UNO expects 5 Volt I2C signals from the AS5600. However the device only provides 3V3 pulses on the bus. So the signal was not stable fast enough (not "square enough"). After applying pull ups the AS5600L worked up to 1000 KHz.

DIR pin

From datasheet, page 30 - Direction (clockwise vs. counter-clockwise)

The AS5600 allows controlling the direction of the magnet rotation with the DIR pin. If DIR is connected to GND (DIR = 0) a clockwise rotation viewed from the top will generate an increment of the calculated angle. If the DIR pin is connected to VDD (DIR = 1) an increment of the calculated angle will happen with counter-clockwise rotation.

This AS5600 library offers a 3rd option for the DIR (direction) pin of the sensor:

  1. Connect to GND ==> fixed clockwise(*). This is the default.
  2. Connect to VCC ==> fixed counter-clockwise.
  3. Connect to an IO pin of the processor == Hardware Direction Control by library.

In the 3rd configuration the library controls the direction of counting by initializing this pin in begin(directionPin), followed by setDirection(direction). For the parameter direction the library defines two constants named:

  • AS5600_CLOCK_WISE (0)
  • AS5600_COUNTERCLOCK_WISE (1)

(*) if begin() is called without directionPin or with this parameter set to 255, Software Direction Control is enabled.

See Software Direction Control below for more information.

OUT pin

The sensor has an output pin named OUT. This pin can be used for an analogue or PWM output signal (AS5600), and only for PWM by the AS5600L.

See Analogue Pin and PWM Pin below.

Examples are added to show how to use this pin with setOutputMode().

See more in the sections Analog OUT and PWM OUT below.

Note: (From Zipdox2 - See issue #36)

Some AS5600 modules seem to have a resistor between PGO and GND. This causes the AS5600 to disable the output (to use it for programming, see datasheet). This resistor needs to be removed to use the OUT pin.

PGO pin

Not tested. ==> Read the datasheet!

PGO stands for Programming Option, it is used to calibrate / program the sensor. As the sensor can be programmed only a few times one should use this functionality with extreme care. See datasheet for a detailed list of steps to be done.

See Make configuration persistent below.

I2C

The I2C address of the AS5600 is always 0x36.

Address

sensor address changeable
AS5600 0x36 NO
AS5600L 0x40 YES, check setAddress()

To use more than one AS5600 on one I2C bus, see Multiplexing below.

The AS5600L supports the change of I2C address, optionally permanent. Check the setAddress() function for non-permanent change.

I2C multiplexing

Sometimes you need to control more devices than possible with the default address range the device provides. This is possible with an I2C multiplexer e.g. TCA9548 which creates up to eight channels (think of it as I2C subnets) which can use the complete address range of the device.

Drawback of using a multiplexer is that it takes more administration in your code e.g. which device is on which channel. This will slow down the access, which must be taken into account when deciding which devices are on which channel. Also note that switching between channels will slow down other devices too if they are behind the multiplexer.

Alternative could be the use of a AND port for the I2C clock line to prevent the sensor from listening to signals on the I2C bus.

Finally the sensor has an analogue output OUT. This output could be used to connect multiple sensors to different analogue ports of the processor.

Warning: If and how well this analog option works is not verified or tested.

Performance

board sensor results notes
Arduino UNO AS5600 up to 900 KHz. https://github.com/RobTillaart/AS5600/issues/22
Arduino UNO AS5600L up to 300 KHz.
ESP32 AS5600 no data
ESP32 AS5600L up to 800 KHz

No other boards tested yet.

ESP32 and I2C

When polling the AS5600 with an ESP32 to measure RPM an issue has been reported. See https://github.com/RobTillaart/AS5600/issues/28

The problem is that the ESP32 can be blocking for up to one second if there is a problem in the connection with the sensor. Using setWireTimeout() does not seem to solve the problem (2023-01-31). In the issue the goal was to measure the turns of a rotating device at around 3800 RPM.

3800 RPM == 64 rounds / second.

To measure speed one need at least 3 angle measurements per rotation. This results in at least 192 measurements per second which is about 1 per 5 milliseconds.

Given that the ESP32 can block for a second, it can not be guaranteed to be up to date. Not for speed, but also not for total number of rotations.

Interface

#include "AS5600.h"

Constants

Most important are:

//  setDirection
const uint8_t AS5600_CLOCK_WISE         = 0;  //  LOW
const uint8_t AS5600_COUNTERCLOCK_WISE  = 1;  //  HIGH

//  0.087890625;
const float   AS5600_RAW_TO_DEGREES     = 360.0 / 4096;
//  0.00153398078788564122971808758949;
const float   AS5600_RAW_TO_RADIANS     = PI * 2.0 / 4096;
//  4.06901041666666e-6
const float   AS5600_RAW_TO_RPM         = 1.0 / 4096 / 60;

//  getAngularSpeed
const uint8_t AS5600_MODE_DEGREES       = 0;
const uint8_t AS5600_MODE_RADIANS       = 1;
const uint8_t AS5600_MODE_RPM           = 2;

See AS5600.h file (and datasheet) for all constants. Also Configuration bits below for configuration related ones.

Constructor + I2C

  • AS5600(TwoWire *wire = &Wire) Constructor with optional Wire interface as parameter.
  • bool begin(uint8_t directionPin = AS5600_SW_DIRECTION_PIN) set the value for the directionPin. If the pin is set to AS5600_SW_DIRECTION_PIN, the default value, there will be software direction control instead of hardware control. See below.
  • bool isConnected() checks if the address 0x36 (AS5600) is on the I2C bus.
  • uint8_t getAddress() returns the fixed device address 0x36 (AS5600).

Direction

To define in which way the sensor counts up.

  • void setDirection(uint8_t direction = AS5600_CLOCK_WISE) idem.
  • uint8_t getDirection() returns AS5600_CLOCK_WISE (0) or AS5600_COUNTERCLOCK_WISE (1).

See Software Direction Control below for more information.

Configuration registers

Please read the datasheet for details.

  • bool setZPosition(uint16_t value) set start position for limited range. Value = 0..4095. Returns false if parameter is out of range.
  • uint16_t getZPosition() get current start position.
  • bool setMPosition(uint16_t value) set stop position for limited range. Value = 0..4095. Returns false if parameter is out of range.
  • uint16_t getMPosition() get current stop position.
  • bool setMaxAngle(uint16_t value) set limited range. Value = 0..4095. Returns false if parameter is out of range. See datasheet Angle Programming
  • uint16_t getMaxAngle() get limited range.

Configuration bits

Please read datasheet for details.

  • bool setConfigure(uint16_t value) value == 0..0x3FFF Access the register as bit mask. Returns false if parameter is out of range.
  • uint16_t getConfigure() returns the current configuration register a bit mask.
Bit short Description Values
0-1 PM Power mode 00 = NOM, 01 = LPM1, 10 = LPM2, 11 = LPM3
2-3 HYST Hysteresis 00 = OFF, 01 = 1 LSB, 10 = 2 LSB, 11 = 3 LSB
4-5 OUTS Output Stage 00 = analog (0-100%), 01 = analog (10-90%), 10 = PWM
6-7 PWMF PWM frequency 00 = 115, 01 = 230, 10 = 460, 11 = 920 (Hz)
8-9 SF Slow Filter 00 = 16x, 01 = 8x, 10 = 4x, 11 = 2x
10-12 FTH Fast Filter Threshold 000 - 111 check datasheet
13 WD Watch Dog 0 = OFF, 1 = ON
15-14 not used

The library has functions to address these fields directly.

The setters() returns false if parameter is out of range.

  • bool setPowerMode(uint8_t powerMode)
  • uint8_t getPowerMode()
  • bool setHysteresis(uint8_t hysteresis) Suppresses "noise" on the output when the magnet is not moving. In a way one is trading precision for stability.
  • uint8_t getHysteresis()
  • bool setOutputMode(uint8_t outputMode)
  • uint8_t getOutputMode()
  • bool setPWMFrequency(uint8_t pwmFreq)
  • uint8_t getPWMFrequency()
  • bool setSlowFilter(uint8_t mask)
  • uint8_t getSlowFilter()
  • bool setFastFilter(uint8_t mask)
  • uint8_t getFastFilter()
  • bool setWatchDog(uint8_t mask)
  • uint8_t getWatchDog()

Read Angle

  • uint16_t rawAngle() returns 0 .. 4095. (12 bits) Conversion factor AS5600_RAW_TO_DEGREES = 360 / 4096 = 0.087890625 or use AS5600_RAW_TO_RADIANS if needed.
  • uint16_t readAngle() returns 0 .. 4095. (12 bits) Conversion factor AS5600_RAW_TO_DEGREES = 360 / 4096 = 0.087890625 or use AS5600_RAW_TO_RADIANS if needed. The value of this register can be affected by the configuration bits above. This is the one most used.
  • bool setOffset(float degrees) overwrites the existing offset. It sets an offset in degrees, e.g. to calibrate the sensor after mounting. Typical values are -359.99 - 359.99 probably smaller. Larger values will be mapped back to this interval. Be aware that larger values will affect / decrease the precision of the measurements as floats have only 7 significant digits. Verify this for your application. Returns false if degrees > 360000.
  • float getOffset() returns offset in degrees.
  • bool increaseOffset(float degrees) adds degrees to the existing offset. If setOffset(20) is called first and increaseOffset(-30) thereafter the new offset is -10 degrees. Returns false if degrees > 360000.

In issue #14 there is a discussion about setOffset(). A possible implementation is to ignore all values outside the -359.99 - 359.99 range. This would help to keep the precision high. User responsibility.

In #51 increaseOffset is discussed.

//  offset == 0;
as.setOffset(20);
//  offset == 20;
as.setOffset(-30);
//  offset = -30;

//  versus

//  offset == 0;
as.setOffset(20);
//  offset == 20;
as.increaseOffset(-30);
//  offset = -10;

Angular Speed

  • float getAngularSpeed(uint8_t mode = AS5600_MODE_DEGREES) is an experimental function that returns an approximation of the angular speed in rotations per second. The function needs to be called at least four times per rotation or once per second to get a reasonably precision.
mode value description notes
AS5600_MODE_RADIANS 1 radians /sec
AS5600_MODE_DEGREES 0 degrees /sec default
other - degrees /sec

Negative return values indicate reverse rotation. What that exactly means depends on the setup of your project.

Note: the first call will return an erroneous value as it has no reference angle or time. Also if one stops calling this function for some time the first call after such delays will be incorrect.

Note: the frequency of calling this function of the sensor depends on the application. The faster the magnet rotates, the faster it may be called. Also if one wants to detect minute movements, calling it more often is the way to go.

An alternative implementation is possible in which the angle is measured twice with a short interval. The only limitation then is that both measurements should be within 180° = half a rotation.

Cumulative position (experimental)

Since 0.3.3 an experimental cumulative position can be requested from the library. The sensor does not provide interrupts to indicate a movement or revolution Therefore one has to poll the sensor at a frequency at least three times per revolution with getCumulativePosition()

The cumulative position (32 bits) consists of 3 parts

bit meaning notes
31 sign typical + == CW, - == CCW
30-12 revolutions
11-00 raw angle call getCumulativePosition()

Functions are:

  • int32_t getCumulativePosition() reads sensor and updates cumulative position.
  • int32_t getRevolutions() converts last position to whole revolutions. Convenience function.
  • int32_t resetPosition(int32_t position = 0) resets the "revolutions" to position (default 0). It does not reset the delta (rotation) since last call to getCumulativePosition(). Returns last position (before reset).
  • int32_t resetCumulativePosition(int32_t position = 0) completely resets the cumulative counter. This includes the delta (rotation) since last call to getCumulativePosition(). Returns last position (before reset).

As this code is experimental, names might change in the future (0.4.0)? As the function are mostly about counting revolutions the current thoughts for new names are:

int32_t updateRevolutions()  replaces getCumulativePosition()
int32_t getRevolutions()
int32_t resetRevolutions()   replaces resetPosition()

Status registers

  • uint8_t readStatus() see Status bits below.
  • uint8_t readAGC() returns the Automatic Gain Control. 0..255 in 5V mode, 0..128 in 3V3 mode.
  • uint16_t readMagnitude() reads the current internal magnitude. (page 9 datasheet) Scale is unclear, can be used as relative scale.
  • bool detectMagnet() returns true if device sees a magnet.
  • bool magnetTooStrong() idem.
  • bool magnetTooWeak() idem.

Status bits

Please read datasheet for details.

Bit short Description Values
0-2 not used
3 MH overflow 1 = magnet too strong
4 ML underflow 1 = magnet too weak
5 MD magnet detect 1 = magnet detected
6-7 not used

Error handling

Since 0.5.2 the library has added experimental error handling. For now only lowest level I2C errors are checked for transmission errors. Error handling might be improved upon in the future.

Note: The public functions do not act on error conditions. This might change in the future. So the user should check for error conditions.

int e = lastError();
if (e != AS5600_OK)
{
  //  handle error
}
  • int lastError() returns the last error code. After reading the error status is cleared to AS5600_OK.
Error codes value notes
AS5600_OK 0 default
AS5600_ERROR_I2C_READ_0 -100
AS5600_ERROR_I2C_READ_1 -101
AS5600_ERROR_I2C_READ_2 -102
AS5600_ERROR_I2C_READ_3 -103
AS5600_ERROR_I2C_WRITE_0 -200
AS5600_ERROR_I2C_WRITE_1 -201

Make configuration persistent. BURN

Read burn count

  • uint8_t getZMCO() reads back how many times the ZPOS and MPOS registers are written to permanent memory. You can only burn a new Angle 3 times to the AS5600, and only 2 times for the AS5600L. This function is safe as it is readonly.

BURN function

The burn functions are used to make settings persistent. These burn functions are permanent, therefore they are commented in the library. Please read datasheet twice, before uncomment them.

USE AT OWN RISK

Please read datasheet twice as these changes are not reversible.

The risk is that you make your AS5600 / AS5600L USELESS.

USE AT OWN RISK

These are the two "unsafe" functions:

  • void burnAngle() writes the ZPOS and MPOS registers to permanent memory. You can only burn a new Angle maximum THREE times to the AS5600 and TWO times for the AS5600L.
  • void burnSetting() writes the MANG register to permanent memory. You can write this only ONE time to the AS5600.

Some discussion about burning see issue #38
(I have no hands on experience with this functions)

USE AT OWN RISK

Software Direction Control

Experimental 0.2.0

Normally one controls the direction of the sensor by connecting the DIR pin to one of the available IO pins of the processor. This IO pin is set in the library as parameter of the begin(directionPin) function.

The directionPin is default set to 255, which defines a Software Direction Control.

To have this working one has to connect the DIR pin of the sensor to GND. This puts the sensor in a hardware clockwise mode. Then it is up to the library to do the additional math so the readAngle() and rawAngle() behave as if the DIR pin was connected to a processor IO pin.

The user still calls setDirection() as before to change the direction of the increments and decrements.

The advantage is one does not need that extra IO pin from the processor. This makes connecting the sensor a bit easier.

TODO: measure performance impact.

TODO: investigate impact on functionality of other registers.

Analog OUT

(details datasheet - page 25 = AS5600)

The OUT pin can be configured with the function:

  • bool setOutputMode(uint8_t outputMode)

AS5600

When the analog OUT mode is set the OUT pin provides a voltage which is linear with the angle.

VDD mode percentage output 1° in V
5V0 0 0 - 100% 0.0 - 5.0 0.01388889
5V0 1 10 - 90% 0.5 - 4.5 0.01111111
3V3 0 0 - 100% 0.0 - 3.3 0.00916667
3V3 1 10 - 90% 0.3 - 3.0 0.00750000

To measure these angles a 10 bit ADC or higher is needed.

When analog OUT is selected readAngle() will still return valid values.

AS5600L

The AS5600L does NOT support analog OUT. Both mode 0 and 1 will set the OUT pin to VDD (+5V0 or 3V3).

PWM OUT

(details datasheet - page 27 = AS5600)

The OUT pin can be configured with the function:

  • bool setOutputMode(uint8_t outputMode) outputMode = 2 = PWM

When the PWM OUT mode is set the OUT pin provides a duty cycle which is linear with the angle. However they PWM has a lead in (HIGH) and a lead out (LOW).

The pulse width is 4351 units, 128 high, 4095 angle, 128 low.

Angle HIGH LOW HIGH % LOW % Notes
0 128 4223 2,94% 97,06%
10 242 4109 5,56% 94,44%
20 356 3996 8,17% 91,83%
45 640 3711 14,71% 85,29%
90 1152 3199 26,47% 73,53%
135 1664 2687 38,24% 61,76%
180 2176 2176 50,00% 50,00%
225 2687 1664 61,76% 38,24%
270 3199 1152 73,53% 26,47%
315 3711 640 85,29% 14,71%
360 4223 128 97,06% 2,94% in fact 359.9 something as 360 == 0

Formula:

based upon the table above angle = map(dutyCycle, 2.94, 97.06, 0.0, 359.9);

or in code ..

t0 = micros();  // rising;
t1 = micros();  // falling;
t2 = micros();  // rising;  new t0

//  note that t2 - t0 should be a constant depending on frequency set.
//  however as there might be up to 5% variation it cannot be hard coded.
float dutyCycle = (1.0 * (t1 - t0)) / (t2 - t0);  
float angle     = (dutyCycle - 0.0294) * (359.9 / (0.9706 - 0.0294));

PWM frequency

The AS5600 allows one to set the PWM base frequency (~5%)

  • bool setPWMFrequency(uint8_t pwmFreq)
mode pwmFreq step in us 1° in time
0 115 Hz 2.123 24.15
1 230 Hz 1.062 12.77
2 460 Hz 0.531 6.39
3 920 Hz 0.216 3.20

Note that at the higher frequencies the step size becomes smaller and smaller and it becomes harder to measure. You need a sub-micro second hardware timer to measure the pulse width with enough precision to get the max resolution.

When PWM OUT is selected readAngle() will still return valid values.


AS5600L class

  • AS5600L(uint8_t address = 0x40, TwoWire *wire = &Wire) constructor. As the I2C address can be changed in the AS5600L, the address is a parameter of the constructor. This is a difference with the AS5600 constructor.

Setting I2C address

  • bool setAddress(uint8_t address) Returns false if the I2C address is not in valid range (8-119).

Setting I2C UPDT

UPDT = update page 30 - AS5600L

  • bool setI2CUPDT(uint8_t value)
  • uint8_t getI2CUPDT()

These functions seems to have only a function in relation to setAddress() so possibly obsolete in the future. If you got other insights on these functions please let me know.


Operational

The base functions are:

AS5600 as5600;

void setup()
{
  Serial.begin(115200);
  ...
  as5900.begin(4);     //  set the direction pin
  as5600.setDirection(AS5600_CLOCK_WISE);
  ...
}

void loop()
{
...
  Serial.println(as5600.readAngle());
  delay(1000);
...
}

See examples.

Future

Some ideas are kept here so they won't get lost. priority is relative.

Must

  • re-organize readme
  • rename revolution functions
    • to what?

Should

  • investigate readMagnitude()
    • combination of AGC and MD, ML and MH flags?
  • investigate OUT behaviour in practice
    • analogue
    • PWM
    • need AS5600 on breakout with support
  • write examples:
    • as5600_calibration.ino (needs HW and lots of time)
    • different configuration options
  • check / verify Power-up time
    • 1 minute (need HW)
  • check Timing Characteristics (datasheet)
    • is there improvement possible.

Could

  • investigate PGO programming pin.
  • check for compatible devices
    • AS5200 ?
  • investigate performance
    • basic performance per function
    • I2C improvements
    • software direction
  • implement extended error handling in public functions.
    • will increase footprint !! how much?
    • writeReg() only if readReg() is OK ==> prevent incorrect writes
      • if (_error != 0) return false;
    • set AS5600_ERROR_PARAMETER e.g. setZPosition()
    • a derived class with extended error handling?

Wont (unless)

  • fix for AS5600L as it does not support analog OUT.
    • type field?
    • other class hierarchy?
      • base class with commonalities?
    • ==> just ignore for now.
  • add mode parameter to offset functions.
    • see getAngularSpeed()

Support

If you appreciate my libraries, you can support the development and maintenance. Improve the quality of the libraries by providing issues and Pull Requests, or donate through PayPal or GitHub sponsors.

Thank you,