HX711
Arduino library for HX711 24 bit ADC used for load cells and scales.
Description
This HX711 library has an interface which is a superset of a library made by bogde. Some missing functions were added to get more info from the lib.
Another important difference is that this library uses floats. The 23 bits mantisse of the IEE754 float matches the 24 bit ADC very well. Furthermore it gave a smaller footprint.
Main flow
First action is to call begin(dataPin, clockPin) to make connection to the HX711.
Second step is calibration for which a number of functions exist.
- tare() measures zero point
- set_scale(factor) set a known conversion factor e.g. from EEPROM.
- calibrate_scale(WEIGHT, TIMES) determines the scale factor based upon a known weight e.g. 1 Kg.
Steps to take for calibration
- clear the scale
- call tare() to set the zero offset
- put a known weight on the scale
- call calibrate_scale(weight)
- scale is calculated.
- save the offset and scale for later use e.g. EEPROM.
Pricing
Some price functions were added to make it easy to use this library for pricing goods or for educational purposes. These functions are under discussion if they will stay. Another set of function to add weights together didn't make it in the 0.2.0 release, it is on a todo list.
For weight conversion functions see https://github.com/RobTillaart/weight
Notes
Scale values for loadcells
These scale values worked pretty well with a set of loadcells, Use calibrate to find your values.
- 5 KG loadcell scale.set_scale(420.52);
- 20 KG loadcell scale.set_scale(127.15);
Connections HX711
- A+/A- uses gain of 128 or 64
- B+/B- uses gain of 32
Connections
HX711 Pin | Color |
---|---|
E+ | red |
E- | black |
A- | white |
A+ | green |
B- | not connected |
B+ | not connected |
HX711 Pin | Color |
---|---|
E+ | red |
E- | black |
A- | blue |
A+ | white |
B- | not connected |
B+ | not connected |
Temperature
Loadcells do have a temperature related error. This can be reduced by doing the calibration and take the tare at the temperature one also does the measurements.
Another way to handle this is to add a good temperature sensor (e.g. DS18B20, SHT85) and compensate for the temperature differences in your code.
Operation
See examples