.github/workflows | ||
examples | ||
test | ||
.arduino-ci.yml | ||
keywords.txt | ||
library.json | ||
library.properties | ||
LICENSE | ||
README.md | ||
rotaryDecoder.cpp | ||
rotaryDecoder.h |
rotaryDecoder
Arduino library for a PCF8574 based rotary decoder - supports 4 RE.
Description
Experimental - not tested yet
Interface
- rotaryDecoder(const int8_t address, TwoWire *wire = Wire);
- bool begin(uint8_t sda, uint8_t scl, uint8_t cnt = 4) ESP32 ea initializes the class. sets I2C pins. cnt is the number of rotary encoders connected. returns true if the PCF8574 is on the I2C bus.
- bool begin(uint8_t cnt = 4) UNO ea. initializes the class. cnt is the number of rotary encoders connected. returns true if the PCF8574 is on the I2C bus.
- bool isConnected() returns true if the PCF8574 is on the I2C bus.
Core functions
- void readInitialState() read the inital state of the 4 rotary encoders. typically called in setup only, or after a sleep e.g. in combination with setValue()
- bool checkChange() polling to see if one or more RE have changed, without updating the counters.
- void update() update the internal counters of the RE. These will add +1 or -1 depending on direction.
- void updateSingle() update the internal counters of the RE. This will add +1 +2 or +3 as it assumes that the rotary encoder only goes into a single direction.
Counters
- uint32_t getValue(uint8_r re) returns the RE counter.
- void setValue(uint8_r re, uint32_t val = 0) (re)set the internal counter to val, default 0
Debugging
- int8_t getLastPosition(uint8_r re)
Performance
As the decoder is based upon a PCF8574, a I2C device, the performance is affected by the clockspeed of the I2C bus. All four core functions have one call to _read() which is the most expensive part.
Early tests gave the following indicative times (Arduino UNO) for the update() function (with no updates it is ~8 us faster). Note that above 500KHz the gain becomes less while reliability of signal decreases. (500KHz is ~3x faster than 100 KHz)
I2C speed | time (us) | delta | %% |
---|---|---|---|
100 KHz | 247 | ||
200 KHz | 146 | 99 | 40% |
300 KHz | 110 | 36 | 24% |
400 KHz | 95 | 15 | 14% |
500 KHz | 84 | 11 | 12% |
600 KHz | 79 | 5 | 6% |
700 KHz | 73 | 6 | 8% |
At @400KHz it can update 4 rotary encoders in ~100us. At a 50% update percentage this implies a max of about 5000 update() calls per second in theory to be tested in practice
Note that a high speed drill goes up to 30000 RPM = 500 RPS = 2000 interrupts per second, assuming 4 pulses == 360<36>. (not tested)
Operational
See examples..