ACS712
Library for the ACS712 Current Sensor - 5A, 20A, 30A
Description
The ACS712 is a chip to measure current, both AC or DC. The chip has an analog output that provides a voltage that is lineair with the current. The ACS712 library supports only a built in ADC by means of analogRead(). There are 2 core functions:
- int mA_DC()
- int mA_AC()
To measure DC current a single analogRead() with some conversion math is sufficient to get a value. To stabilize the signal analogRead() is called twice.
To measure AC current a blocking loop for 20 millis is run to determine the peak to peak value which is converted to the RMS value. To convert the peak2peak value to RMS one need the so called crest or form factor. This factor depends heavily on the signal form. For a perfect sinus the value is sqrt(2)/2.
Interface
Base
- ACS712(analogPin, volts = 5.0, maxADC = 1023, mVperA = 100) constructor
- mA_AC(freq = 50) blocks ~21 ms to sample a whole 50 or 60 Hz period.
- mA_DC()
Midpoint
- setMidPoint(mp) sets midpoint ADC for DC only
- autoMidPoint(uint8_t freq = 50) Auto midPoint, assuming zero DC current or any AC current
- getMidPoint() read back setting
- incMidPoint() manual increase midpoint (manually)
- decMidPoint() manual decrease midpoint (manually)
Formfactor
Also known as crest factor; affects AC only. Default = 0.5 * sqrt(2) = ~0.70710678...
- setFormFactor(ff) manually sets formfactor 0.0 .. 1.0
- getFormFactor() returns current formFactor
Noise
Default = 21 mV.
- setNoisemV(noisemV) set noise level
- getNoisemV() returns set value
mV per Ampere
Both for AC and DC
- setmVperAmp(mva) sets the milliVolt per Ampere measured.
- getmVperAmp() returns set value.
Test
The library is tested with the RobotDyn ACS712 20A breakout and an Arduino UNO.
Operation
With the constructor the parameters volts and maxADC (steps) of the ADC are set together with the milliVolt per Ampere value. The last parameter can be adjusted afterwards, e.g. to callibrate this value runtime. Note this parameter affects both AC and DC measurements.
To callibrate the zero level for DC measurements, 5 functions are available to adjust the midPoint.
To callibrate the RMS value for AC measurements, 2 functions are available to get and set the formFactor.
To callibrate the noise level (used for AC measurements), 2 functions are available to get and set the noise in mV.
The examples show the basic working of the functions.
Future
- mA_AC blocks 20 ms so might affect taskscheduling on a ESP32. This needs to be investigated.
- int point2point(uint8_t freq) function for AC. Is part of mA_AC() allready.