# I2C_ASDX
|
||
|
|
||
|
Arduino library for I2C ASDX pressure sensor
|
||
|
|
||
|
## Description
|
||
|
|
||
|
The ASDX sensor of Honeywell exist in many variations.
|
||
|
Check the datasheet for all the details.
|
||
|
|
||
|
The I2C_ASDX library can read the sensor and give the pressure in millibar, bar or PSI.
|
||
|
|
||
|
The interface consists of the following:
|
||
|
|
||
|
- **I2C_ASDX(address, psi)** COnstructor, I2C address and maximum pressure.
|
||
|
- **begin(sda, scl)** I2C parameters for ESP32
|
||
|
- **begin()** for UNO and other boards supporting Wire.
|
||
|
- **reset()** resets internal variables,
|
||
|
- **available()** tests if ASDX sensor is available (just address check)
|
||
|
- **read()** reads the sensor, checks for errors, calculates the pressure and set lastRead
|
||
|
- **getPressure()** retuns an int in milliBar, will return 0 after reset() and no read done.
|
||
|
- **getMilliBar()** returns a float in milliBar
|
||
|
- **getBar()** returns a float in bar
|
||
|
- **getPSI()** returns a float in PSI = Pounds per Square Inch.
|
||
|
- **errorCount()** total counter for
|
||
|
- **lastRead()** time in millis since last succesful reading the sensor
|
||
|
- **state()** last known state of read, also returned by read()
|
||
|
|
||
|
|
||
|
## Testing
|
||
|
|
||
|
The library is tested with only 3 different sensors, all of the PG type.
|
||
|
Code is prepared but not tested for 15, 5 and 1 PSI too.
|
||
|
|
||
|
```
|
||
|
ID UNIT TYPE DESCRIPTION
|
||
|
output is porportional to difference
|
||
|
PG PSI Gage * between applied pressure and atmospheric pressure
|
||
|
MG mBar Gage * idem
|
||
|
BG Bar Gage * idem
|
||
|
KG KiloPascal Gage * idem
|
||
|
D Differential * between pressure applied to each of the ports.
|
||
|
A Absolute * between applied pressure and built-in reference to vacuum.
|
||
|
|
||
|
|
||
|
ADDRESS PRESSURE RANGE TYPE P A T V
|
||
|
0x58 100 psi 0..6895 mBar SSCDANN 100PG 5 A 5
|
||
|
0x38 60 psi 0..4137 mbar SSCDANN 060PG 3 A 5
|
||
|
0x28 30 psi 0..2068 mbar SSCDANN 030PG 2 A 5
|
||
|
|
||
|
P = pressure range
|
||
|
A = I2C address indicator
|
||
|
T = accuracy range
|
||
|
V = voltage (3 volt also supported, not tested)
|
||
|
```
|
||
|
|
||
|
That saidm it is expected that the library is modifyable to support many
|
||
|
more as long as they have the following raw read values.
|
||
|
|
||
|
```
|
||
|
1638 = 0 PSI
|
||
|
14746 = max PSI
|
||
|
```
|
||
|
|
||
|
## Testing
|
||
|
|
||
|
TESTED TYPES - type A 10% - 90% only
|
||
|
|
||
|
|
||
|
|
||
|
## Operation
|
||
|
|
||
|
See examples
|