@ -1,8 +1,8 @@
|
|||||||
[![license-badge][]][license] ![version] [![stars][]][stargazers] [![hit-count][]][count] [![github-issues][]][issues]
|
[![license-badge][]][license] ![version] [![stars][]][stargazers] [![hit-count][]][count] [![github-issues][]][issues]
|
||||||
|
|
||||||
# Aosong ASAIR AHT10 & AHT15
|
# Aosong ASAIR AHT10, AHT15 & AHT20
|
||||||
|
|
||||||
This is an Arduino library for Aosong ASAIR AHT10, AHT15 Digital Humidity & Temperature Sensor
|
This is an Arduino library for Aosong ASAIR AHT10, AHT15 & AHT20 Digital Humidity & Temperature Sensor
|
||||||
|
|
||||||
- Supply voltage: 1.8v - 3.6v
|
- Supply voltage: 1.8v - 3.6v
|
||||||
- Temperature range: -40°C..+80°C
|
- Temperature range: -40°C..+80°C
|
||||||
@ -12,30 +12,32 @@ This is an Arduino library for Aosong ASAIR AHT10, AHT15 Digital Humidity & Temp
|
|||||||
- Relative humidity resolution: 0.024%
|
- Relative humidity resolution: 0.024%
|
||||||
- Relative humidity accuracy: ±2%**
|
- Relative humidity accuracy: ±2%**
|
||||||
- I²C bus speed: 0Hz - 400KHz
|
- I²C bus speed: 0Hz - 400KHz
|
||||||
- Recomended polling frequency: 8sec - 30sec
|
- Recomended polling frequency: 8sec - 30sec***
|
||||||
|
|
||||||
|
|
||||||
Supports all sensors features:
|
Supports all sensors features:
|
||||||
|
|
||||||
- read humidity***
|
- read humidity****
|
||||||
- read temperature***
|
- read temperature****
|
||||||
- soft reset
|
- soft reset with sensor initialization
|
||||||
|
|
||||||
Tested on:
|
Tested on:
|
||||||
- Arduino AVR
|
- Arduino AVR
|
||||||
- Arduino ESP8266
|
- Arduino ESP8266
|
||||||
|
- Arduino ESP32
|
||||||
- Arduino STM32
|
- Arduino STM32
|
||||||
|
|
||||||
|
**Prolonged exposure for 60 hours at humidity > 80% can lead to a temporary drift of the signal +3%. Sensor slowly returns to the calibrated state at normal operating conditions.
|
||||||
|
***If sampling rate of the measurement is too high, the sensor overheats. To prevent the temperature of the sensor from rising > 0.1°C, read sensor once every 2 seconds.
|
||||||
|
|
||||||
|
****The library returns 255 if a communication error occurs or if the calibration coefficient is off.
|
||||||
|
|
||||||
[license-badge]: https://img.shields.io/badge/License-GPLv3-blue.svg
|
[license-badge]: https://img.shields.io/badge/License-GPLv3-blue.svg
|
||||||
[license]: https://choosealicense.com/licenses/gpl-3.0/
|
[license]: https://choosealicense.com/licenses/gpl-3.0/
|
||||||
[version]: https://img.shields.io/badge/Version-1.0.0-green.svg
|
[version]: https://img.shields.io/badge/Version-1.1.0-green.svg
|
||||||
[stars]: https://img.shields.io/github/stars/enjoyneering/AHT10.svg
|
[stars]: https://img.shields.io/github/stars/enjoyneering/AHT10.svg
|
||||||
[hit-count]: http://hits.dwyl.io/enjoyneering/AHT10/badges.svg
|
[hit-count]: http://hits.dwyl.io/enjoyneering/AHT10/badges.svg
|
||||||
[count]: http://hits.dwyl.io/enjoyneering/AHT10/badges
|
[count]: http://hits.dwyl.io/enjoyneering/AHT10/badges
|
||||||
[stargazers]: https://github.com/enjoyneering/AHT10/stargazers
|
[stargazers]: https://github.com/enjoyneering/AHT10/stargazers
|
||||||
[github-issues]: https://img.shields.io/github/issues/enjoyneering/AHT10.svg
|
[github-issues]: https://img.shields.io/github/issues/enjoyneering/AHT10.svg
|
||||||
[issues]: https://github.com/enjoyneering/AHT10/issues/
|
[issues]: https://github.com/enjoyneering/AHT10/issues/
|
||||||
|
|
||||||
**Prolonged exposure for 60 hours at humidity > 80% can lead to a temporary drift of the signal +3%. Sensor slowly returns to the calibrated state at normal operating conditions.
|
|
||||||
|
|
||||||
***Library returns 255 if a communication error occurs
|
|
||||||
|
Loading…
Reference in New Issue
Block a user